II.1.7 CTE and CME calculations
A linear dependence of the temperature on the location through the laminate thickness is assumed:
|
|
Similarly, the water uptake depends linearly on :
|
|
The calculation of laminate response to hygrometric loading is very similar to its response to thermo-elastic loading. Therefore, the following developments are carried out for thermo-elastic loading only, and are then transposed to hygrothermal loading.
II.1.7.1 In-plane and flexural thermo-elastic behavior
II.1.7.2 Out-of-plane shear thermo-elastic behavior
II.1.7.3 Hygrometric behavior of laminates
II.1.7.4 Full sets of equations
II.1.7.2 Out-of-plane shear thermo-elastic behavior
II.1.7.3 Hygrometric behavior of laminates
II.1.7.4 Full sets of equations